Taking radiographs with a rubber dam in place: frame options
How do you take a radiograph with the rubber dam in place? Do you remove the dam first? I have heard that folding frames are available. They sound easier to use, but how do you manage with a non-folding frame?
Translated version of the Turkish original
There is no need to remove the rubber dam from the tooth to take a radiograph. The film or sensor can be positioned and the image taken while the clamp and the dam around the tooth remain in place.
Once I became accustomed to using an apex locator, I found I needed fewer repeat intraoperative radiographs to determine working length in cases where I obtained reliable, reproducible measurements. However, an apex locator does not replace preoperative and postoperative radiographs or necessary intraoperative checks. A radiographic check remains important if there is doubt about the measurement or if the canal anatomy needs to be assessed. (1)
With a non-folding metal frame, the dam can be released from the relevant corners of the frame to make positioning the sensor easier. If that is insufficient or the metal frame is in the image field, the frame can be detached completely for a short time. Keep the clamp in place and maintain the seal of the dam around the tooth. Keep the loose edges outside the mouth so that saliva cannot reach the working field. After the radiograph, reattach the dam to the frame and check the isolation.
Endodontic film or sensor holders that allow room for the clamp and canal instruments make this easier. Radiolucent plastic frames also have the advantage that they can remain in place during the exposure. (2)
Folding frames can provide easier access for positioning the film or sensor. (3) However, with some models I have used, I have experienced durability problems after repeated autoclaving. I find metal frames more practical for placing the dam and keeping it under tension.